- Weighs only 800g with battery
- One-hand-operation
- Only few keys for user friendly menu navigation
- High resolution (800 x 480 pixels ) WVGA display
- Removable Micro SD card up to 32GB
- USB communication port
- Auto plotting dynamic DAC
- On Board DGS/AVG for defect size evaluation
- Software for AWS D1.1 Sizing
- Continuous/Dynamic A-Scan and B-Scan recording within the machine (up-to 100 hours in 8 GB Micro SD card)
- Best for Documentation, Evidence, Analysis and Reporting
- Real time color coded un-encoded B-Scan along with A-Scan on the screen
- Square Wave Pulser
Arjun30 - Ultrasonic Flaw Detector - Salient Features
| Technical Specifications | |
|---|---|
| Test Range | 2.5 mm to 10 meter (in steel). Fine mode adjustable in step of 1mm. |
| Velocity | 1000 m/s to 15000 m/s. In Hot Key mode it has 21 pre-set values.Fine mode adjustable in step of 1 m/s. |
| Delay | Up to 3 meter adjustable in 0.01, 0.1 or 1mm step. |
| Gain | 100 dB calibrated gain adjustable in 0.1, 0.5, 1, 2, 6 or 14 dB step. |
| Rejection | 0 to 125% FSH with LED indicator. |
| Rectification | Full wave rectified with filtering. |
| Frequency | 0.5 MHz to 15 MHz (Wideband). |
| Linearity deviation | Vertical: ±3%, Horizontal: ±0.5%. |
| Test Modes | Pulse echo and transmit/receive. |
| Probe Connectors | LEMO Size 00 (2 no’s). |
| Monitor | Dual gate adjustable in 1% of Screen width with Positive/Negative logic, |
| Gate Expand | Gate Expand modes. Expands Range to width of the gate. |
| A-Scan memory | 500 Trace Patterns can be stored, recalled or transferred to PC via USB port.A-Scan trace pattern can be directly stored on SD card or on External USB disk. |
| Calibration Set-up | 50 different calibration set-ups can be Stored and Recalled. |
| Software | ArjnSoft30 Interface software for Data transfer, Analysis, Reporting and Printing. |
| USB and SD card | External USB disk and Micro SD card (up to 32GB) ports provided for data storage. |
| Display | 5 inch Colour Wide VGA LCD/TFT display (800×480 pixel, size 108×64 mm) with higher resolution LCD for better signal representation and better visibility with different colour sets. |
| Reference A-Scan | Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing. |
| Echo Dynamic | Echo Dynamic pattern display. |
| Dynamic DAC | Dynamic DAC curve can be Digitally plotted (Smooth parabolic curve) on screen with selectable additional offset curves from 0 to 14 dB in 0.1 dB selectable steps.DAC curve can be set as flaw monitor gate can be plotted using minimum 2 to maximum 10 points. |
| DGS | Defect size evaluation using predefined probe settings and custom probe set-ups,ERS (Equivalent Reflector Size) can also be displayed on the screen. |
| AWS | Built in Software for Evaluation of defects in accordance with AWS Specification D1.1. |
| Built-In UT Data Recording | Carries out 100 Hours of continuous /Dynamic A-Scan and B-Scan recording (in 8 GB SD Card) which can be replayed and analysed in Machine as well as PC. |
| Colour B-Scan | Real time Colour coded Un-Encoded B-Scan along with A-Scan on the Screen which can be transferred to PC, Also analysis of A-Scan and B-Scan can be done in the machine as well as PC |
| Digital Readout And Trig. Function | Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path, Surface Distance and Depth are directly displayed when angle probe is in use. |
| Update Rate | 50Hz. |
| Power | Lithium-Ion Battery pack 7.4VDC, 5AH. External charger is provided to charge the battery without engaging the main unit. |
| Battery Life | 8 Hours on Full Charge |
| Charger | Input Voltage 100 to 240 VAC. Charge status indicator is provided. |
| Temperature | 0 to 55°C. |
| Size | 117 x 176 x 56 mm (HxWxD). |
| Weight | 800 gms with Li-Ion Battery. |
| Compliance | Ultrasound: EN 12668, ASTM E317 |
Frequently Asked Questions
What makes the Arjun 30 different from other Modsonic flaw detectors?
The Arjun 30 is Modsonic’s lightest conventional flaw detector at just 800g with battery. It combines one-hand operation, a high-resolution 5-inch WVGA colour display, a Square Wave Pulser, on-board DGS/AVG, dynamic DAC, AWS D1.1 software, and up to 100 hours of built-in A-Scan and B-Scan recording — making it ideal for documentation-heavy field inspection.
What is the test range and frequency range of the Arjun 30?
The Arjun 30 covers a test range of 2.5 mm to 10 metres in steel with Fine mode adjustable in 1 mm steps, and a wideband frequency range of 0.5 MHz to 15 MHz.
How much data can the Arjun 30 store and record?
The Arjun 30 can store 500 A-Scan trace patterns and 50 calibration set-ups. It also supports continuous A-Scan and B-Scan recording for up to 100 hours on an 8 GB Micro SD card. Data can be transferred to a PC via USB port or stored directly on a Micro SD card (up to 32 GB) or external USB disk.
What is the B-Scan feature on the Arjun 30?
The Arjun 30 displays a real-time colour coded un-encoded B-Scan alongside the A-Scan on screen simultaneously. The B-Scan can be recorded, transferred to a PC, and analysed both in the machine and in ArjnSoft30 PC software — making it valuable for evidence, documentation, and reporting.
What are the DGS and DAC capabilities of the Arjun 30?
The Arjun 30 features on-board DGS/AVG for defect size evaluation using predefined and custom probe set-ups, with ERS (Equivalent Reflector Size) displayed directly on screen. Its auto-plotting dynamic DAC generates a smooth parabolic curve with selectable offset curves from 0 to 14 dB in 0.1 dB steps, using 2 to 10 reference points.
What is the battery life and weight of the Arjun 30?
The Arjun 30 weighs only 800g including the Lithium-Ion battery (7.4V DC, 5 AH) and delivers 8 hours of continuous operation on a full charge. An external charger is provided so the battery can be charged without occupying the main unit.
What compliance standards does the Arjun 30 meet?
The Arjun 30 is compliant with EN 12668 and ASTM E317 ultrasound standards, and includes built-in software for weld defect evaluation in accordance with AWS Specification D1.1.