- 8/16 channels
- Separate 8/16 A-Scan traces with different colors.
- Built-In bi-directional length/position display of probe.
- 200 built-in memory locations to store A-Scan and set-ups.
- Light Weight (2 Kgs.)
- Ideal for Semi/Full Automation Applications.
Arya 16 - Ultrasonic Flaw Detector - Salient Features
| Technical Specifications | |
|---|---|
| Test Range | 10mm to 1000mm (@5920 M/sec Steel Velocity equivalent) continuously variable. It can be adjusted with hot key for coarse range step. Horizontal linearity 1%. |
| Velocity | 1000m/s to 9999m/s. continuous adjustment. It can be adjusted using hot key in 7 preset values. |
| Delay | 0-1000mm Continuous variable. It can be adjusted using hot key in coarse delay step. |
| Gain | 0-80 db with 0.1,0.5,1,2,6,12 dB step selection. Vertical Linearity: 5% |
| Rejection | Linear type (0-99%) of full screen height, 1% step. |
| Rectification | Full wave rectified A-Scan. |
| Frequency | 0.2 to 20 MHz |
| No of channels | 16 channels with separate A-Scan traces, Any or all can be selected. |
| Test Modes | Pulse echo or transmit/receive. |
| Transmitter | Negative Square wave type. |
| Freeze/Peak Freeze | Current display Freeze and Peak freeze to create echo dynamic pattern. |
| Connector | BNC type connectors for all channels. |
| Monitor | Dual gate for each channel adjustable in 1% screen width with Positive/Negative logic, Gate Expand modes. |
| Gate Expand | Expands Range to width of the gate. |
| A-Scan memory (built-in) | 200 Multicolored A-Scan with calibration parameters with measured value. Using external USB pen drive virtually unlimited A-scan and Calibration set-ups can be stored. |
| Calibration Set-up | 100 calibration parameters set-ups. |
| Software | Suitable PC software provided to review/ print report of the stored A-scan files. |
| Display | TFT Color with LED backlight 152mm x 91 mm Viewing area, 800 x 480 pixels. All channels have separate base line with color selectable by user. |
| A-Scan Display | Envelop or filled A-scan Pattern. |
| DAC | Separate Dynamic DAC curve for each channel with additional -6 and -14 dB. DAC curve can be set as flaw monitor gate. Using 2 to 10 points DAC curve can be plotted. |
| Measurement | Echo amplitude, Sound path, Echo to Echo distance. When angle probe is used then using trigonometric functions it calculates and displays Surface and Depth distance of defect. |
| Measuring Unit | Millimeters. |
| PRF | Maximum 8000 Hz which varies in step of 50 Hz as per parameter set value due to Auto limiting. |
| Update Rate | 50Hz |
| Power Source | Operates on Built in Li-Ion rechargeable battery or on Mains using supplied charger. Operation time is 8 hours with fully charged battery. |
| Charger | Input Voltage 100 to 240 VAC. Charge status indicator is provided. |
| Battery charge status | Battery charge status by suitable LED indication on charger. |
| Battery Status | Battery status indicator with auto low battery shut down to protect battery. |
| Encoder | Positional encoder interface to indicate travel distance/position of probe. |
| Keyboard | User friendly with direct access to frequently used functions. |
| Operating Temperature | 0 to 55⁰ C. (For operation) |
| Dimensions | 247mm x 151mm x 70mm |
| Weight | Approx 2 Kgs. |
Frequently Asked Questions
What makes the Arya 16 unique compared to other Modsonic flaw detectors?
The Arya 16 is Modsonic’s multichannel flaw detector with 16 independent channels, each with its own A-Scan trace displayed in a separate user-selectable colour. It features a built-in bi-directional length and position display of the probe via encoder interface, making it ideal for semi-automation and full automation inspection applications where multiple probes need to operate simultaneously.
How many channels does the Arya 16 support and how are they displayed?
The Arya 16 supports 8 or 16 channels, with each channel having a separate A-Scan trace displayed in a distinct user-selectable colour on a single 800×480 pixel TFT colour display. Any or all channels can be selected independently, and each channel has its own dual gate with positive/negative logic and Gate Expand mode.
What is the test range and frequency range of the Arya 16?
The Arya 16 covers a test range of 10 mm to 1000 mm (at 5920 m/s steel velocity equivalent) with 1% horizontal linearity, continuously variable with Hot Key coarse range adjustment. It supports a frequency range of 0.2 MHz to 20 MHz.
What are the DAC capabilities of the Arya 16?
The Arya 16 provides a separate dynamic DAC curve for each of its 16 channels, with additional -6 dB and -14 dB offset curves. Each DAC curve can be set as a flaw monitor gate and plotted using 2 to 10 reference points, giving independent flaw evaluation control per channel.
How much data can the Arya 16 store?
The Arya 16 has 200 built-in memory locations for storing multicoloured A-Scans with calibration parameters and measured values, plus 100 calibration set-up locations. Using an external USB pen drive, virtually unlimited A-Scans and calibration set-ups can be stored. PC software is supplied to review and print reports of stored A-Scan files.
Does the Arya 16 support positional encoding?
Yes. The Arya 16 has a built-in positional encoder interface that displays the bi-directional travel distance and position of the probe during scanning. This makes it suitable for encoded B-Scan and automation scanning applications where exact probe location needs to be tracked.
What is the battery life and weight of the Arya 16?
The Arya 16 weighs approximately 2 kg and operates for 8 hours on its built-in Lithium-Ion rechargeable battery. It can also be powered directly from mains using the supplied charger (100–240 VAC). A battery status indicator with auto low-battery shutdown is included to protect the battery.