Technical Specifications |
Test Range |
2.5mm to 10 meter (0.100 in to 400 in) (longitudinal waves in steel). Fine mode is adjustable in minimum step of 0.01mm (0.001in). |
Velocity |
1000 met. /sec to 15000 met. /sec (40 in/millisecond to 600 in/millisecond). In Hot key mode it has pre-set values. Fine mode it is adjustable in step of 1met/sec.(1in/millisecond). |
Delay |
Variable from -10 to 2000mm (-0.3 to 30 inches). |
Gain |
100 dB calibrated gain adjustable in 0.1, 0.5, 1, 2, 6 or 12 dB step. |
Rejection |
0 to 100% FSH with Led indicator. |
Rectification |
Full-wave rectified, Half wave – ve, Half wave + ve, and RF mode. |
Frequency |
It has tuned amplifier with four bands: a) 0.2MHz to 1MHz b) 0.5MHz to 4MHz c) 0.8MHz to 8MHz d) 2MHz to 20MHz |
Linearity Deviation |
Vertical ±3% Horizontal: ±0.5%. |
Test Modes |
Pulse echo and Transmit/Receive. |
Transmitter |
Transmission pulse negative spikes. (Pulse rise time<10ns) and with Selectable high (300 Vp) or low (250 Vp) power. |
Damping |
Damping high/low is selectable. (High= 45Ώ, Low=345Ώ). |
Connectors |
BNC or LEMO size-1 factory optional |
Freeze/ Peak Freeze |
A-scan Freeze, Peak freeze, echo dynamic available. In peak freeze it holds peak amplitude pattern which is useful for angle beam probing to to locate peak signal. |
Monitor |
Dual gate with threshold adjustable in 1% of the screen height with +ve/-ve, Gate expand Interface trigger modes. |
Gate Expand |
Expands range to width of the gate. |
A-scan Memory |
500 trace patterns can be stored which can be recalled, printed, or transferred to PC via USB (with NOTE/DETAIL). Unlimited No of A-scan can be directly stored in USB disk with auto file naming. |
B-scan Memory |
50 B-scan can be stored (with NOTE/DETAIL) which can be recalled, or transferred to PC via USB. Unlimited no of B-scan can be directly stored in USB disk with auto file naming. |
Calibration Set-up |
50 different calibration set-ups can be stored and recalled. |
T-LOG |
20000 readings can be stored in 20 different files. Five different types of file templates for file creation. Stored readings can be transferred to PC via USB. |
DAC |
Dynamic DAC curve can be digitally plotted (smooth parabolic curve) on screen with selectable additional offset curves from 0 to 14 dB in 0.1dB selectable steps. DAC curve can be set as a flow monitor gate. DAC can be plotted using minimum 2 to maximum 10 points. |
TCG |
After plotting DAC , TCG( Time corrected Gain) can be activated. This brings All echo signals to equal height irrespective of depth. |
AWS |
Built-in Software for evaluation of defect in accordance with AWS standard. |
DGS |
Defect size evaluation based on 18 predefined probe data and one custom Probe set-up per memory location. Defect size is directly displayed in ERS Value(Equivalent Reflector Size). |
Digital Readout |
Thickness/Depth can be displayed in digital readout when using a normal probe and sound path, Surface Distance and depth of echo signals of GATEa /GATEb are directly displayed when angle probe is in use. Measurement point can be selected to be peak or flank. Echo height, ERS value, dB diff of DAC/DGS curve to signal height, Echo height respect to DAC in terms of percentage or in dB can be measured, T-minimum, Travel-distance can be measured when encoder is connected and time of travel during Freerun B-scan . |
Measurement Unit |
Metric or British unit of measurement is selectable. |
Software |
dVaSoft Interface software for transferring A-scan / B-scan/ T-LOG from da Vinci to PC is supplied with da Vinci delta. |
Printer |
USB printer (PCL3 compatible) can be directly attached to da Vinci delta for Attachment printing of stored A-scan waveform with calibration data and note detail. |
Display |
High brightness active matrix colour TFT LCD display. Display area 320×240 Pixel (117×88mm). Five different colours and Grid scheme options. colour leg facility for angle probe for easy interpretation of skip distance. |
Full Screen |
By pressing enter key for a few seconds A-scan will be displayed in Full screen area. |
Reference A-Scan |
Reference A-Scan pattern of standard test object can be saved and recalled in background for easy comparison during testing. |
Video Output |
VGA video signal output for monitor/projector connection. |
PRF |
4Hz TO 500Hz. Selection in 10 scalable steps. PRF can go down up to 4Hz When PRF is selected to 1 and maximum achievable coupled to range when PRF is selected to 10. |
Update Rate |
60Hz |
Color coded B-scan |
In real time display color coded B-scan as well as live display A-scan. captured B-scan gets stored in external USB pen drive. |
TOFD Display |
In real-time RF A-scan and TOFD D-scan. After collecting data, stored data or A-scan pattern can be reviewed using cursor. |
Recording |
Free run or with positional encoder for actual location. |
Record Length |
1000mm test length with collection step of 1mm. Each A-scan with 500 point depth. |
I/O port |
Optical encoder can be connected to ‘da Vinci ‘delta for positional detail. It can be used for Encoded B-scan. |
Data Storage |
Each Scan file is stored in external USB storage device with auto file naming. |
Power |
Lithium-Ion battery pack 10.8 VDC, 7.8 AH, gives 8 hours continuous Operation from fully charged battery. Battery with the charge indicator/fuel gauge indicator. da Vinci delta can also operate on 6 nos of C type dry cells. |
Battery Charger |
Input volt 100 to 240VAC / 50 Hz. |
Temperature |
0 to 55° C. |
Size |
170×260×110mm (H×W×D). |
Weight |
2.1Kg with battery. |